ADDITION OF HEAT STRIP THERMOSTAT CONTROL

Post by bfadmin »

Most of our coaches have a heat strip in the overhead A/C, but only a few control the heat it produces with a thermostat. The heat and blower is either on or off in most of our units. I set out to install a thermostat in our unit, the process and result, I share.

I could have done it two ways, have the thermostat control both the fan and heat or just the heat strip. I chose the latter, thinking every time the blower came on in the night, it would wake us up. We also use just the fan for "white" noise when we are camping near a highway or train track, so I wanted that to run constantly whenever the heating circuit was on.

Materials are 6' of #12-2 Romex, 4 wire nuts, an outlet box and an electric heat wall thermostat. NOTE: The heat strip is 1500 watts, making smaller #14 wire a bit marginal.

First I removed the A/C interior shroud. On the passenger side, I found black & white wires going from the switch to the heater. I cut the black one somewhere in the middle and stripped the ends. There is a built in chase AKA wire channel on each side of the A/C going toward each side of the coach (thwartships to you sea faring men). I removed the microwave oven and ran the Romex through the chase into the oven cavity. Cut a hole in the plywood facing forward and installed the outlet box and thermostat. Then I installed wire nuts to connect the Romex to the black heater wires I had parted. After I put everything back together.

Note that the thermostat needed for this purpose should be a 120-volt AC, line voltage thermostat rated for at least 20 amps.
However you could use a low voltage (24 VAC) furnace thermostat, as long as you incorporated a relay to handle the 120 VAC line voltage (and wattage) needed for the heat strip. This method would be more costly and a longer way around the barn, but it would work fine.

Also make sure the thermostat is the type (i.e. RV type) that does not use a mercury bulb as a switch. Mercury thermostats, normally used in homes, have to be installed perfectly level to work accurately. As one quickly realizes------that style would not suitable for an RV for obvious reasons.

Turn the A/C switch onto heat, the fan runs, turn the thermostat up and the heater comes on. The whole job cost less than $8, thanks to that yard sale thermostat.

George Boley
Boley@mailstation.com
"Driving Miss Daisy" in a 1999 22' RD
knowledge can't be lost, provided it is shared

NOTE: If you have any questions, please contact the author directly using the e-mail address provided above rather than clicking on the blue email button at the bottom border of this post. The info above was posted for the author by the website administrator (bfadmin) and clicking on the blue email button below will address your e-mail message to the bfadmin rather than to the author.

This particular forum is locked so you can not post any comments or questions directly to it. However, there is an unlocked topic below called Coach Modification & Technical Library Questions & Comments that you can post comments and/or questions to referring back to this particular topic if you so desire